Clamp the side rail of the operating bed with a fixed clamp. First, turn the short rotating rod to tighten the bedside fixing claws and clamp the side rail to confirm that it is stable and will not loosen. Then, turn the long rotating rod to adjust and fix the angle of the instrument to confirm that the fixing is stable and will not loosen;
2.Install the light source to the joint head, rotate the handle and confirm that the fixation is stable and will not loosen; 3. Disinfect the light source part with alcohol during use, and put the remaining parts into a sterilization bag; 4.Connect the device to the 220v power supply; 5. Turn on the light source switch 6. Press the adjustment button (button is recessed) to maintain the fixed state, press the button again (button protrusion) to be in the adjustable state, and adjust to the required angle.
Clean
The outer surface of the Multifunctional Electric Intelligent Holding Assist and Lighting Device (including the place where it is installed) should be cleaned and disinfected after the operation. The cleaning agent must use a neutral household antistatic agent. Do not use phenolic-based, iodide-based or dialdehyde-based disinfectants. Finally, use Wipe dry all surfaces with a clean cloth.
1. When cleaning and disinfecting , the power must be cut off first and prevent liquid from penetrating into the lamp; 2. Do not use brushes, steel balls and other abrasive materials for cleaning; 3. When cleaning , please use a soft cloth, sponge or damp cloth. Do not use a hard brush or wire brush, and do not use scouring powder, paint, or bananas.Water, acid, etc. Are not applied to any surface. 4. After disinfecting with 75% alcohol, wipe dry with a dry cloth. 5. Medical gauze is often used on the surface of the front cover glass to remove dust to increase illumination.
Maintainance
1.Multifunctional Electric Intelligent Holding Assist and Lighting Device needs to be regularly inspected and maintained by professional maintenance personnel and records should be kept; if any problems are found, please solve them promptly according to the product instructions. If they cannot be eliminated, please contact our company in time.
Regularly check the connection status of each connecting screw of the Multifunctional Electric Intelligent Holding Assist and Lighting Device, and tighten loose screws in time; regularly check whether the contact is good; regularly check the flexibility of each moving part of the surgical light (our company recommends that users check once every two months and perform maintenance on the entire machine every year maintainance). 2.After each operation, in addition to normal disinfection and cleaning of the surgical light, the user must also wipe and disinfect the holder of the surgical light with alcohol. 3.Please keep it properly and do not store it together with drugs or chemical liquids. 4.The light source is regularly replaced by the factory and recycled by the factory.
Storage and shipping conditions
It should be stored in a room with a relative humidity not exceeding 80%, a temperature of 0ºC~±50ºC, no corrosive gases and good ventilation. It is fragile and easily scratched or damaged by sharp or hard objects. Please use the original packaging during transportation and have it transported by an experienced carrier.
Product Photos
Best Service for You 1.The most complete marketing service system
2.Rich customer resource and industry experience
3.Rich experience in customer form and industry
4.Powerful advantage of design research
5.Outstanding ability of organization and management
6.Perfect quality control system
7.The most influential industry leader
8.Innovative marketing team.
Company: Jiangsu Guanchuang Medical Technology Co., Ltd. Add: Wujin high-tech venture park 2D, 256th Mingxin mid-road, Hutang town, Wujin district, Changzhou city, Jiangsu province.